SPR-PVC-AS
Protective metal conduit, strip-wound, s profile, PVC sheathing
Protective metal conduit, strip-wound, s profile, PVC sheathing
Material: cold strip galvanized | PVC
Temperature: -25°C ... +90°C ^ +100°C
IP class: [acc. to EN 60529] IP 68
Protective metal conduit, strip-wound, s profile, PVC sheathing
Material: cold strip galvanized | PVC
Temperature: -25°C ... +90°C ^ +100°C
IP class: [acc. to EN 60529] IP 68
Protective metal conduit, strip-wound, s profile, PA sheathing
Material: cold strip galvanized | PA
Temperature: -50°C ... +120°C ^ +150°C
IP class: [acc. to EN 60529] IP 68
Protective metal conduit. strip-wound, s profile, PU sheathing, V2 (UL 94)
Material: cold strip galvanized | PU
Temperature: -50°C ... +100°C ^ +130°C
IP class: [acc. to EN 60529] IP 68
Protective metal conduit, s profile, flame retardant PU sheathing, V0 (UL 94), EN 45545-2 (R22;HL2), (R23;HL3)
Material: galvanized steel | PU
Temperature: -50°C ... +100°C ^ +130°C
IP class: [acc. to EN 60529] IP 68
Protective metal conduit, strip-wound, s profile, PVC sheathing, galvanized steel wire braiding
Material: cold strip galvanized | PVC | galvanized steel
Temperature: -25°C ... +90°C ^ +100°C
IP class: [acc. to EN 60529] IP 68
Protective metal conduit, strip-wound, double overlapped profile (Agraff), PU sheathing, V2 (UL 94)
Material: cold strip galvanized | PU
Temperature: -50°C ... +100°C ^ +130°C
IP class: [acc. to EN 60529] IP 68
Protective metal conduit, strip-wound, double overlapped profile (Agraff), PU sheathing, flame retardant, V0 (UL 94), EN 45545-2 (R22;HL2), (R23;HL3)
Material: cold strip galvanized | PU
Temperature: -50°C ... +100°C ^ +130°C
IP class: [acc. to EN 60529] IP 68
Protective metal conduit, strip-wound, double overlapped profile (Agraff), SI sheathing
Material: cold strip galvanized | SI
Temperature: -50°C ... +180°C
IP class: [acc. to EN 60529] IP 68
Protective metal conduit, strip-wound, double overlapped profile (Agraff), copper wire braiding, PU sheathing, for EMC applications
Material: cold strip galvanized | CU | PU
Temperature: -50°C ... +100°C ^ +130°C
IP class: [acc. to EN 60529] IP 68
Protective metal conduit, strip-wound, hooked profile, special fibre sealing, smooth, reinforced, flame-resistant PVC sheathing
Material: cold strip galvanized | PVC
Temperature: -25°C ... +90°C ^ +100°C
IP class: [acc. to EN 60529] IP 68
Protective metal conduit, strip-wound, hooked profile,, special fibre sealing, smooth, oil-resistant PVC sheathing
Material: cold strip galvanized | PVC
Temperature: -25°C ... +90°C ^ +100°C
IP class: [acc. to EN 60529] IP 68
Protective metal conduit, strip-wound, hooked profile, incorporated copper ground lead,, smooth rein-forced PVC sheathing
Material: cold strip galvanized | PVC
Temperature: -25°C ... +90°C ^ +100°C
IP class: [acc. to EN 60529] IP 68
Protective metal conduit, strip-wound, hooked profile, special fibre sealing, liquid tight, smooth, food-save PU sheathing
Material: cold strip galvanized | PU
Temperature: -40°C ... +80°C ^ +110°C
IP class: [acc. to EN 60529] IP 68