HG-PA
Wire braiding consisting of round braided monofiles with double crossed looping at the different braiding angles, Coverage: >85%
Wire braiding consisting of round braided monofiles with double crossed looping at the different braiding angles, Coverage: >85%
Material: polyamide 6.6 monofiles
Temperature: -50°C ... +120°C ^ +150°C
Wire braiding consisting of round braided monofiles with double crossed looping at the different braiding angles, Coverage: > 85%, EN 45545-2 (HL2,R22), (HL3,R23)
Material: PET-Monofile, Durchmesser 0,22 mm
Temperature: -50°C ... +120°C ^ 150°C
Wire braiding consisting of round braided monofiles with double crossed looping at the different braiding angles, dispenser box
Material: PET-Monofile, Durchmesser 0,22 mm
Temperature: -50°C ... +120°C ^ 150°C
Wire braiding, self-closing, consisting of round braided monofiles with double crossed looping at the different braiding angles, Coverage: > 89%
Material: PET monofiles, diameter 0.22 mm
Temperature: -55°C ... +150°C ^ 175°C
Wire braiding consisting of round braided tinned-copper wires with double crossed looping at the different braiding angles, Coverage: >85%
Material: tinned copper
Temperature: -50°C ... +250°C
Wire braiding consisting of fine, round braided wires with double crossed looping at the different braiding angles, Coverage: > 85%
Material: tinned copper
Temperature: -50°C ... +250°C
Wire braiding with PVC carrier conduit consisting of round braided tinned-copper wires with double crossed looping at the different braiding angles, Coverage: >85%
Material: tinned copper | PVC
Temperature: -50°C ... +250°C
Wire braiding consisting of round braided galvanized steel wires with double crossed looping at the different braiding angles, Coverage: >85%
Material: galvanized steel
Temperature: -50°C ... +250°C
Protective metal conduit for the medical and sensor technology, strip-wound, s profile, PVC sheathing, non flame propagating acc. to DIN EN IEC 61386-23
Material: stainless steel | PVC
Temperature: -25°C ... +90°C ^ +100°C
Protection class: [acc. to EN 60529] IP 68
Protective metal conduit for the sensor technology, strip-wound, s profile, electrical conductive PVC sheathing, V2 (UL 94)
Material: stainless steel | PVC
Temperature: -25°C ... +80°C ^ +100°C
Protection class: [acc. to EN 60529] IP 68
Special protective conduit helix for the medical-, sensor technology and the beam wave guide technology
Material: stainless steel
Temperature: -200°C ... +600°C
Special protective conduit for the medical-, sensor technology and and the beam wave guide technology, helix made of stainless steel, fiber glass braiding, silicone rubber sheathing
Material: stainless steel V2A | Braiding: fiber glass | Sheathing: silicone-rubber
Temperature: -50°C ... +180°C
Protection class: [acc. to EN 60529] IP 68
Special protective conduit for the medical-, sensor technology and and the beam wave guide technology, helix made of stainless steel, fiber glass braiding, silicone rubber sheathing
Material: stainless steel V2A | Braiding: fiber glass | Sheathing: silicone-rubber
Temperature: -50°C ... +180°C
Protection class: [acc. to EN 60529] IP 68
Spiral bindings, bundels and binds single wires, protect wire harnesses, wires and lines
Material: Polyamide PA 12
Temperature: -40°C ... +100° ^ +130°C
Spiral bindings, bundels and binds single wires, protect wire harnesses, wires and lines
Material: LD-Polyethylen PE
Temperature: -40°C ... +90°C ^ +100°C
Fire protection conduit, non-flammable, calcium-silicate braiding with silicone sheathing
Material: calcium-silicate | SI
Temperature: -50°C ... +350°C ^ +700°C
Tape with tightly woven selvedges, thickness: 2-3 mm
Material: calcium-silicate
Temperature: -50°C ... +300°C ^ +700°C
Wrapping tape for fastening of fire protection conduit FLEXAhightemp
Material: calcium-silicate with silicone coating
Temperature: -50°C ... +300°C